Application
These single core flexible cables are used for wiring in control panels, machines and various electrical installations in small, medium and large industries.

Features
Manufactured from bright-annealed 99.97% pure bare copper conductors these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses.

Technical Specifications
Download Product Brochure

 

 

 

 

 

 

Technical Data
Working voltage
Upto 1100 V
Temperature range
-15 deg C to +70 deg C
Sizes
0.5 to 50.0 sq mm with ISI mark
70.0 to 240 sq mm generally conforming to IS 694
Color codes
Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange
Specification
IS 694:1990
BS 6004:1991 and BS 6500:1990 also available
Packing
In 100-meter coils. Higher sizes on drums

 

SINGLE CORE/MULTICORE FLEXIBLE CABLES AS PER
IS 694/1990 VOLTAGE GRADE UPTO 1100 VOLTS


Area sq. mm
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
_
Conductor
No.& Size of Wire(Nom.)mm Max
16/.2
24/.2
32/.2
30/.25 OR 48/.2
50/.25 OR 80/.2
56/.3
84/0.3
80/0.4 OR 140/0.3
126/.4
196/.4
276/.4
396/.4
_
Max Resistance @ 20 ° C Ohm/Km
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
.078
0.55
0.38
_
Current Rating DC or AC
4
7
12
15
20
27
35
46
62
80
102
138
Insulation
Thickness (Nom.) mm
0.6
0.6
0.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
Single Core Unsheathed
Overall Diameter (mm)
2.20
2.45
2.60
2.90
3.55
4.20
5.20
6.70
7.80
9.70
10.9
13.20
Single Core Sheathed
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx mm)
4.0
4.25
4.5
4.80
5.45
6.30
_
_
_
_
_
_
Twin Flat Sheathed
Overall Width mm
6.2
6.7
_
_
_
_
_
_
_
_
_
_
_
Overall Height mm
4.0
4.25
_
_
_
_
_
_
_
_
_
_
2 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
6.5
7.0
7.3
7.8
9.5
11.0
_
_
_
_
_
_
3 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
6.9
7.4
7.7
8.2
10.0
11.5
_
_
_
_
_
_
4 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
 
Overall Diameter (Approx.) mm
7.5
8.0
8.5
9.5
11.0
13.0
           
5 Core
Sheath Thickness (Nom.) mm
0.9
0.9
1.0
1.0
1.0
1.1_
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
8.30
9.00
9.50
10.5
12.0
14.0
_
_
_
_
_
_
Note : Sheath thickness given are nominal, and overall diameters given are approximate.
The conductor strand diameters are in line with IS : 8130/1984.
The no. of wires indicated are approximate and diameter of strands is nominal and shall be such that it satisfies the requirements as per IS 694/1990. The conductor strand size and conductor resistance requirements as per IS 8130 will be satisfied.

 

SINGLE CORE FLEXIBLE CABLES GENERALLY CONFORMING TO IS 694: 1990
VOLTAGE GRADE UPTO 1100 VOLTS

AREA sq. mm.
70.0
95.0
120.0
150.0
185.0
240.0
NO. & SIZE OF WIRE
No./mm
360/.5
475/.5
608/.5
750/.5
925/.5
1221/.5
CONDUCTOR MAX RES. @200C
Ohms/km
0.272
0.206
0.161
0.129
0.106
0.0801
CURRENT DC/AC
Amps
214
260
305
355
415
500
INSULATION THICKNESS (Nom.)
mm
1.4
1.6
1.6
1.8
2.0
2.2
O.D. (Approx.)
mm
15.3
17.9
19.4
21.9
24.5
28.0
Cables upto 150 sq.mm. can also be supplied as per IS 2465 : 1984 with ISI mark

 

Conductor Cross Section mm Radial Thickness of insulation
(Nom.) mm
Cables with stranded conductor (H07V-R) Conductor construction No./size of wire mm Cables with stranded conductor (H07V-R) Cable OD (maximum) mm Cables with flexible conductor (H07V-K) Conductor construction No./size of wire mm Cables with flexible conductor (H07V-K) Cable OD (maximum) mm
SINGLE CORE UNSHEATHED CABLES, 450/750V DC AND 690/1000V AC
0.5
0.6
7/0.30
2.6
16/.2*
2.6
0.75
0.6
7/.37
2.8
24/.2*
2.8
1.0
0.6